Fiala Respiration Heat Rate

Reports the heat loss of a body due to respiration. This report is used when simulating thermal comfort using one of the Fiala Thermoregulation models.

A positive value indicates that heat is gained by the environment. As such, the respiration heat rate acts as a heat source to the environment.

Fiala Respiration Heat Rate Properties

Units
The Fiala Respiration Heat Rate is given in units of power, for example, watts.
Parts
Selects the geometry part of the manikin for which thermal comfort is predicted. You can only select geometry parts that are already used in thermal network regions.
Representation
Selects a representation. Additional selections appear as representations that are added to the simulation.
Smooth Values
When activated, the report is calculated using node (interpolated) values of the chosen quantity rather than cell values.