Heat Exchanger

There are two types of heat exchanger reports: single and dual stream:

  • The single stream heat exchanger report uses calculations with one region. By this method, one stream is assumed to have a uniform temperature and the other stream is modeled by specifying the heat exchanger enthalpy source.
  • The dual stream heat exchanger report uses calculations with an interface between two regions. This technique involves the heat exchange between a cold fluid stream and a hot fluid stream. These streams are modeled as two different physics continua (each having different material properties).

    For this report, the monitor values Mass Flux, Inlet Temperature, Outlet Temperature, and Pressure Drop may be selected for both the regions that comprise the dual stream heat exchanger.

    This report also gives efficiency for the two streams as follows:

    Figure 1. EQUATION_DISPLAY
    effcold=(TcoldoutTcoldin)(ThotinTcoldin)
    (433)
    Figure 2. EQUATION_DISPLAY
    effhot=(ThotinThotout)(ThotinTcoldin)
    (434)

Each of these reports is represented in the simulation tree by a node, which has its own properties but is subject to the report node’s pop-up menu.

Heat Exchanger Report Properties

Heat Exchanger

Selects a region (single stream) or interface (dual stream) from a drop-down list of applicable objects in the simulation.

Monitor Units

Units in which the Monitor Value is monitored and plotted, but the preferred units are used in the report output for the heat transfer rate, pressures and temperatures.

Monitor Value

Selects the quantity to be monitored.

Mass Flux

Selects mass flux m˙.

Heat Transfer

Selects heat transfer Q.

Inlet Temperature

Selects inlet temperature Tin.

Outlet Temperature

Selects outlet temperature Tout.

Pressure Drop

Selects pressure drop Δp.

Monitor Contact The contact parts listed for the heat exchanger interface under Geometry > Contacts. (Dual stream only.)

Region-0 Downstream Parts

Downstream parts of the Region-0 stream, one of the two regions that constitute the heat exchanger interface. (Dual stream only.)

Region-1 Downstream Parts

Downstream parts of the Region-1 stream, one of the two regions that constitute the heat exchanger interface. (Dual stream only.)

Representation

Selects a representation. Additional selections appear as representations that are added to the simulation.