Setting Initial Conditions and Reference Values
The simulation requires initial conditions and reference values for gravity. The initial hexane droplet size distribution is uniform within a specified diameter range and zero outside the range.
To set the initial conditions and reference values:
-
Edit the
mode and set the following properties:
Node Property Value Turbulence Intensity Value 0.1 Turbulence Specification Method Intensity + Length Scale -
Edit the
node and set the following properties:
Node Property Setting Volume Fraction
Value 0.99 Particle Size Distribution
Option Uniform distribution Maximum Diameter
Value 0.003 m Minimum Diameter
Value 0.002 m Volume Fraction
Value 0.01
Set the reference values for the
Physics 1 continuum. To simulate a vertical pipe, set the gravity vector along the X-axis. As the reference density is used to evaluate the buoyancy source term, it is set to the density of the water-hexane mixture. The density of hexane is
655 kg/m^3 and the volume fraction of hexane in the mixture is 0.01, so the mixture density is
996.5 kg/m^3.
-
Edit the
node and set the following properties:
Node Property Setting Gravity Value [-9.81, 0.0] m/s^2 Reference Density Value 996.5 kg/m^3 - Save the simulation.