Selecting the Physics Models
Set up a Eulerian Multiphase simulation. The geometry is axisymmetric and the flow is turbulent due to the restriction in the pipe. Gravity is included to model the buoyancy of the hexane droplets as they rise up the vertical pipe.
To select the physics models:
- Right-click Select Models. and choose
- In the Enabled Models group box, deactivate Two Dimensional.
-
Select the following models in order:
Group Box Model Space Axisymmetric
Time Steady
Material Multiphase
Multiphase Interaction (Selected automatically)
Multiphase Model Eulerian Multiphase (EMP)
Gradients (Selected automatically)
Viscous Regime Turbulent
EMP Turbulence Mixture Turbulence Reynolds-Averaged Navier-Stokes (selected automatically)
Reynolds-Averaged Turbulence Reynolds Stress Turbulence Reynolds Stress Turbulence Models Linear Pressure Strain Two-Layer Wall Distance (selected automatically)
Two-Layer All y+ Wall Treatment (selected automatically)
Optional Models Gravity
- Click Close.
-
To review the models, open the
node.
- Save the simulation.