Post FW-H Receiver Reference

The following specific properties and right-click actions are available for Post FW-H receivers.

Post FW-H Receiver Properties

Object Properties
Post FW-H Receivers
Far-Field Density
The density of the far-field fluid.
Far-Field Sound Speed
The sound speed in the far-field. See Eqn. (4659).
Acoustic Correlation Length
Sets the correlation length to include spanwise correlation of the flow over a finite span, for two-dimensional simulations only. It repeats the 2D domain in the third direction with a limited number of cells, the number based on correlation length value. The solver takes the source data from the XY plane segment and copies it into an array that corresponds to the full extent, then applies the FW-H solver on this new source sound data set.
Acoustic Data Source
The data source for the Post FW-H model. The following options are available:
Flow
The Post FW-H model uses the flow field variables pressure, density, and velocity provided by the segregated or coupled flow solver.
Flow+APE
The Post FW-H model uses the following field functions from the Acoustic Wave model:
  • APE Total Pressure
  • APE Total Velocity
  • APE Total Density
See Acoustic Wave Solver Field Functions Reference.
For stationary, non-slip wall boundary conditions, APE Total Velocity is zero and the data does not need to be exported.
APE
The Post FW-H model uses the following field functions from the Acoustic Wave model or the Perturbed Convective Wave model:
  • Acoustic Pressure
  • Acoustic Density
  • Acoustic Velocity
See Acoustic Wave Solver Field Functions Reference or Perturbed Convective Wave Model Reference.
For stationary, non-slip wall boundary conditions, Acoustic Velocity is zero and the data does not need to be exported.
[post FW-H receiver]
Point Part
The point probe used as receiver, representing a single microphone.
Imported FW-H 
Surfaces
The FW-H surfaces used as inputs.
FW-H Formulation
The formulation to use for the surface terms. The following options are available:
Farassat_1A
Uses Farassat's Formulation 1A, Eqn. (4760) and Eqn. (4761). This is the default formulation.
Dunn_Farassat_Padula_1A
Uses the Dunn-Farassat-Padula Formulation 1A, Eqn. (4762) and Eqn. (4763).
[post FW-H receiver table] None

Post FW-H Receiver Right-click Actions

Object Right-Click Actions
Post FW-H Receivers None
[post FW-H receiver] None
[post FW-H receiver table]
Export
Lists exported data sets.
Extract
Lists extracted data sets.
Tabulate...
Tabulates and displays extracted data sets.