Setting Initial Conditions and Reference Values
Set the initial conditions and reference values for the physics continuum.
Set the reference gravity, density, and pressure for the coolant.
To set the initial conditions and reference values:
-
Edit the
node and set the following properties:
Node Property Setting Velocity
Value [2.0076, 0.0] m/s Volume Fraction
Value 0.9999 Velocity
Value [2.0076, 0.0] m/s Volume Fraction
Value 1.0E-4
Set the initial conditions for each phase.
-
Edit the
node and set the following properties:
Node Property Setting Static Temperature Value 551.55 K Turbulence Intensity Value 0.05 Turbulent Viscosity Ratio Value 400 -
Edit the
node and set the following properties:
Node Property Setting Value 560.65 K Value 0.05 Value 200
Set the reference values for the
Coolant continuum.
-
Edit the
Reference Values node and set the following properties:
Node Property Setting Gravity Value [-9.81, 0.0] m/s^2 Reference Density Value 745.65 kg/m^3 Reference Pressure Value 7170000.0 Pa - Save the simulation.