Setting the Solver Parameters and Stopping Criteria

As the simulation is transient, set the solver time-step and elapsed time.

To define the solver parameters:

  1. To define the solver parameters, expand the Solvers node and set the following properties:
    Node Property Value
    Implicit Unsteady Time-Step 0.01
    DEM Solver Time Scale 0.1
  2. To define the stopping criteria, select the Stopping Criteria node and set the following properties:
    Node Property Setting
    Maximum Inner Iterations Maximum Inner Iterations 1
    Maximum Physical Time Maximum Physical Time 2.5 s
    Maximum Steps Enabled Deactivated
  3. Save the simulation.