Prism Layer Mesher Reference
You can control the generation of prism layers using the properties and right-click actions for the Prism Layer Mesher.
- Stretching Function
- Selects the stretching function to use in calculating the thickness of
each cell layer within the prism layer. There are two option for
this:
- Geometric Progression—The thickness of each cell layer is calculated using a geometric progression that is based around a constant size ratio. Selecting this option, sets the property to 1.5 by default.
- Hyperbolic Tangent—The thickness of each cell layer is calculated using a hyperbolic tangent stretching function. Selecting this option, sets the property to 0.5 by default.
- Distribution Mode/ Stretching Mode
- Selects the distribution/stretching mode to use in specifying the
relative size parameters that the stretching function requires. There
are three options for this:
- Stretch Factor—The definition of the stretch factor depends on which stretching function is being used. Adds the Prism Layer Stretching node for global and custom settings.
- Wall Thickness—Sets the thickness of the near-wall cell layer. Thicknesses of the remaining layers are distributed according to a calculated stretch factor. Adds the Thickness of Near Wall Prism Layer node for global and custom settings.
- Thickness Ratio—Sets the ratio of the thickness of the cell layer furthest from the wall to the thickness of the cell layer nearest the wall. Adds the Prism Layer Thickness Ratio node for global and custom settings.
Right-Click Actions
- Restore Default Settings
- Allows you to restore all properties to the default value.