Setting Up a Scalar Scene

Set up a scalar scene to display the fluid film temperature.

To set up a scalar scene:

Create a scalar scene for fluid film temperature.
  1. Right-click the Scenes node and select New > Scalar.

A new sub-node Scalar Scene 1 is created under the Scenes node.

  1. Rename the Scenes > Scalar Scene 1 node to Temperature.
  2. Click scene/plot.
  3. Select the Temperature > Scalar 1 > Parts node and in the Parts property, click (Custom Editor).
  4. In the dialog that appears, expand the Regions > Wetted Wall shell node and select Wetted Wall.
  5. Expand the Lagrangian Phases node and select Droplets to visualize the edge film stripping.


  6. Click OK.
  7. Select the Temperature > Scalar 1 > Scalar Field node and in the Function property, click (Custom Editor) and select Temperature.


  8. Click (Save-Restore-Select views) in the toolbar and select Restore View > View 1.
  9. Save the simulation.