Visualizing the Solution
A scene has already been created to visualize the fluid velocity and the Von Mises Stress in the diaphragm. To visualize the Von Mises stress and the Plunger motion the relevant displayer properties must be defined.
To set the field functions modeled in the scene window:
- Select the node and set Function to .
-
Select the
node and set the following properties:
Property Setting Function Stress Von Mises Units Pa Auto Range Min and Max Values
To visualize the translation motion created for the
Plunger within the scene, a graphic motion transform is
created and assigned to the plunger displayer.
-
To set the transform for the Plunger in the scene:
- Right-click the node and select .
- Select the Translation. node and set Motion to
- Select the Motion Transform 1. node and set Transform to
Setting the representations:
- Select the Volume Mesh. node and set Representation to
- Repeat the previous step above for the Vector Velocity, Scalar Displacement Magnitude, and Scalar Stress nodes.
- Select the blue-yellow-red. node and set Color Map to
- Save the simulation.