Relative or Absolute Cutoff Size

You can set a relative or absolute small cell cutoff size.

It is possible that refinements due to the initial surface mesh size, or volumetric controls can result in small cells whose size is less than the target size in the template. If the small and large cells growth rate property has been activated for the Trimmed Cell Mesher model, then a relative or absolute small cell cutoff size can be set for both the Default Growth Rate and the Surface Growth Rate. For cells smaller than the small cell cutoff size, the trimmed cell mesher applies the small cell growth rate to create transition cell layers between the small cells and the rest of the mesh.

The small cell growth rate is set as a property of the nodes for Default Growth Rate or Surface Growth Rate. On surfaces or boundaries, the growth rate applies to transition cell layers that are grown from small cells on the surface. Elsewhere, the default small cell growth rate applies.