Defining Motion
Select the appropriate motion models to simulate the deformation of the fluid and solid regions under the external load on the pipe. For the solid region, define a Solid Displacement motion, that allows the pipe mesh to deform in real time based on the computed displacements. For the fluid region, define a Morphing motion, that allows the fluid mesh to deform based on the displacements mapped at the interface.
- Right-click the node and select .
- Repeat the previous step and select .
To assign the motion models to the fluid and solid regions:
- Expand the node.
- Select the Motion Specification node and set Motion to Morphing.
- Expand the node.
- Select the Motion Specification node and set Motion to Solid Displacement.
Simcenter STAR-CCM+ automatically sets the morpher method for the fluid boundary representing the fluid-structure interface to
Solid Stress. Set the
pipe contact boundary to follow the interface motion:
- Expand the node.
- Select the Floating. node and set Specification to
- Save the simulation.