What Is Table (Equivalence Ratio)?
An equivalence ratio table has a column of ‘er’ (equivalence ratio) values, and ‘lfs’ (laminar flame speed) values given in m/s. This method is available with the User Defined Laminar Flame Speed option of the Coherent Flame model, Turbulent Flame Speed Closure model, Thickened Flame model, or Flame Surface Density Transport model.
When defining the equivalence ratio table, the first column, which contains the values for the equivalence ratio, must be labeled er. However, the second column, which contains the laminar flame speed values, can be labeled with any title.
This example shows the contents of a file with equivalence ratio data:
er lfs
0.6 0.146586604
0.7 0.231662295
0.8 0.329079651
0.9 0.42048291
1 0.483519189
1.1 0.500554535
1.2 0.466632794
1.3 0.391806544
1.4 0.296351954
1.5 0.201946692
1.6 0.12399419
1.7 0.068601963
1.8 0.03420356
1.9 0.015368442