Importing the Fan Performance Data Table
Simcenter STAR-CCM+ calibrates the fan momentum source in your simulation with performance data from a real fan.
To provide this performance data:
Import the appropriate fan curve table into the simulation.
Shown below is a simplified example of a fan performance data table. The two columns are volumetric flow rate, Vol, in cubic meters per second (m^3/s), and pressure rise, Press, in Pascals (pa):
Vol | Press |
0.01 | 458.58 |
0.20 | 286.26 |
0.40 | 267.68 |
0.60 | 239.05 |
0.80 | 220.56 |
1.00 | 190.52 |
1.20 | 146.84 |
1.40 | 98.86 |
1.60 | 46.45 |
1.80 | -27.10 |
2.00 | -111.15 |
2.20 | -204.01 |
Ensure that the pressure decreases with increasing flow rate across the fan for all data points in the table. If you use a fan curve that does not meet this requirement, the results are unstable.